FC9000-UM-251-9370 8-60
8 Electrical Adjustment
(19) The following menu is displayed after the cross marks plots.
(20) Measure the offset between the tool 1 cross mark and the tool 2 lines.
(21) When it needs to adjust for X direction (feeding direction), press the F3 key to display the following
menu.
Set the X-offset value.
Press the UP or DOWN position key to change the number based on the pen 1 of cross mark.
(22) Press the ENTER key after offset value is input, the following menu is displayed.
(23) When it needs to adjust for Y direction (pen block moving direction), press the F4 key to display the
following menu.
Set the Y-offset value.
Press the UP or DOWN position key to change the number based on the pen 1 cross mark.
(24) Press the ENTER key after offset value is input, the following menu is displayed.
(25) Press the F2 key. Verify that the plotted pen 1 cross mark is located at the center of the plotted pen 2
lines.
(26) If the plotted cross marks are in the correct positions, press the ENTER key to store the setting and