LCX603-UM-651-9370 2-61
2 Setup
(9) Basedonthecrosses(+)forthecorrectionreadingthatwasscanned,measurehowfaryoumustslide
thecorrectioncrosses(+)cutforcomparisonsothattheyoverlap(cutthecenteroftheprintedcrosses
(+)),andrecordthevalue.
Feeding direction
Page 1
X amount of variance
X amount of variance
Y
X
Correction input: -X
Correction input: -Y
Cut cross (+)
Printed cross (+)
Forexampleintheaboveillustration,directionxanddirectionyarebothmisalignedindirectionplus
(+).Assuch,itisnecessarytocorrecttodirectionminus(–).
Eachcorrectionvaluewillbecomeanegativevalue.
(10)PresstheF2key(X-POSITIONADJ)andenterthecorrectionvaluefordirectionx.
X-PO S ITIO N ADJ U S T
< 0 . 0>mm
ADJU S T:
↑ ↓
YES: E NTER N O :ESC
Changethenumericalvalue(-1.5to+1.5)withthePOSITIONkeys(↑↓)andinputthecorrectionvalue.
PresstheENTERKeytostorethevalue.Themenuisreturnedtothepreviousscreen.
POSI T ION A D JUS T M ENT
X-PO S I TIO N ADJ>
Y-PO S I TIO N ADJ>
C U T CO N F IRM A T ION>
(11) PresstheF3key(Y-POSITIONADJ)andenterthecorrectionvaluefordirectiony.
Y-PO S ITIO N ADJ U S T
< 0 . 0>mm
ADJU S T:
↑ ↓
YES: E NTER N O :ESC
Changethenumericalvalue(-1.5to+1.5)withthePOSITIONkeys(↑↓)andinputthecorrectionvalue.
PresstheENTERKeytostorethevalue.Themenuisreturnedtothepreviousscreen.
POSI T ION A D JUS T M ENT
X-PO S I TIO N ADJ>
Y-PO S I TIO N ADJ>
C U T CO N F IRM A T ION>