14063 Left deck controller
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit.
2. Reduce cutting load.
3. Clean around debris around
motor and controller.
15062 Left traction motor
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit.
2. Check to ensure wheel rotates
freely. Check brake functionality
by turning machine off and use
mechanical override to freely
move wheel.
3. Reduce load.
4. Clean debris around motor and
controller.
16063 Left traction
controller
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit.
2. Reduce load.
3. Clean debris around motor and
controller.
21066 VCM reported
center deck stall.
This warning displays when a deck
motor has stalled. Cycle PTO to
resume cutting. To troubleshoot:
1. Confirm phase wiring is
connected properly from motor
to controller.
2. Reduce cutting load by reducing
vehicle speed or cut height.
3. Verify machine is powered down,
check blade for obstruction or
material buildup on spindle or
blade.
WARNINGS
IMPORTANT: Warning codes do not require service or troubleshooting. Warning codes
display when unit is not within standard operating conditions.
IMPORTANT: See Fault / Warning Code Index on page 38 for fault and warning code details.
Location
0 = Other
1 = Left
2 = Center
3 = Right
Component
1 = VCM
2 = Battery
3 = Deck Motor
4 = Deck Controller
5 = Drive Motor
6 = Drive Controller
7 = Steering Sensor
Dealer Description Dealer Troubleshooting