EasyManua.ls Logo

Gravely Pro-Turn EV 60 - Page 43

Gravely Pro-Turn EV 60
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN - 41
23062 Center deck motor
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit
2. Check to ensure blade rotates
freely.
3. Reduce cutting load.
4. Clean debris around motor and
controller
24063 Center deck
controller
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit
2. Reduce cutting load.
3. Clean debris around motor and
controller
31067 VCM reported right
deck stall.
This warning displays when a deck
motor has stalled. Cycle PTO to
resume cutting. To troubleshoot:
1. Confirm phase wiring is
connected properly from motor
to controller
2. Reduce cutting load by reducing
vehicle speed or cut height.
3. Verify machine is powered down,
check blade for obstruction or
material buildup on spindle or
blade
33062 Right deck motor
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit
2. Check to ensure blade rotates
freely.
3. Reduce cutting load.
4. Clean debris around motor and
controller
34063 Right deck controller
overheating
warning.
1. Check motor and controller
phase wire connections for open
circuit
2. Reduce cutting load.
3. Clean debris around motor and
controller.
WARNINGS
IMPORTANT: Warning codes do not require service or troubleshooting. Warning codes
display when unit is not within standard operating conditions.
IMPORTANT: See Fault / Warning Code Index on page 38 for fault and warning code details.
Location
0 = Other
1 = Left
2 = Center
3 = Right
Component
1 = VCM
2 = Battery
3 = Deck Motor
4 = Deck Controller
5 = Drive Motor
6 = Drive Controller
7 = Steering Sensor
Dealer Description Dealer Troubleshooting

Table of Contents