46
M_LS900 XP IQ Energy_EN_B
Connections - Installation
Power down: Machine - Water chiller
1. Machine:PuttheOn/O󰓐switchinthe"O"(O󰓐)position.
2. Water chiller: Set the general stop button to the "O"(Stop) position.
Switcho󰘯themachineinthefollowingsituations:
when the operator is permanently leaving the machine
in the event of physical damage (something is dropped on the machine, 󰘰re, a liquid is spilled on the
machine, etc.)
mechanical/electrical/electronicfaultssuggestingabreakdown
if there is a major problem or the machine is jammed mechanically
forced restart
themachineisjammedontheparttobeengraved/marked
themachineisjammedonanobjectintheworkarea
external/internal cleaning
󰘰llingthetank(Waterchiller)
Restarting
Ifthemachineortheoperatingprogramlocks,themachinemayneedtoberestarted.
1. Switcho󰓐themachine.
2. Wait approximately 30 s.
Thiswaitingtimemustberespected.Itpreventsanelectricsurgelikelytodamagethemachine'spowersupply.
3. Switch on the machine.