71
M_LS900 XP IQ Energy_EN_B
Technicalspeci󰘰cations
7. Connections and cabling
Port: USB 1.1
Dedicated Inputs/Outputs Sub-D: 15 point connector - Female
Inputs / Outputs: Air extraction
system
DIN: 5 point connector - Female
Cylinder attachment DIN: 8 point connector - Female
Air assist
Pneumatic connection
internal diameter: 4 mm (0.157 in)
Pressure: 6 Bar (87 PSI) (Maximum)
Air extraction system internal diameter: 100 mm (3.937 in)
Air󰄉owrate:
- General mode
- Head mode
Minimum:
-0,5kPa-(0.07PSI)/300m³/h-(6.54yard³/min).
-20kPa-(2.9PSI)/150m³/h-(3.27yard³/min).
Water chiller (only for ENERGY
machines)
2 brass barb connectors D10
8. Firmware characteristics - driver
Languages (Firmware) FR - EN - DE - IT - ES - NL - BR - HU - TR - PL - JP
File format Gravograph binary encoding
RAM (Firmware) 32 Mo / MB - Storage of multiple jobs
Driver version
Minimum:7.04(󰘰rmware:3.41)
Operating system
(driver)
Windows® 2000 - XP - Vista - 7 - 8 - 10