Chapter 2 Installation
5
Chapter 2 Installation
Servo unit and servo motor should be correctly installed to avoid the mistaken operation,
to protect the machine from being broken or damaged.
2.1 Installing servo unit
Be careful for the protection against rain and sunlight while the servo unit is being
installed.
Servo unit must be installed in the electric cabinet to prevent dust, corrosive gas,
liquid, conductors and inflammable substances from entering it.
Servo unit should be fixed in the well ventilative, dampproof and dustproof
environment.
Fireproof material should be used in the installation with no permission to fix it on or
near the inflammable object.
Run the servo unit below the temperature of 45℃ for reliable long term usage.
The driver is employed with bottom board or panel installation mode in the upright
direction of installation plane.
Fig. 2.1 is sketch map for bottom board installation and Fig. 2.2 for panel installation. (Unit
below: mm)
Installation environment
Item DA98B servo unit
Operating temperature
0~55℃(no frost)
≤90%RH(no dewing)
Storage/delivery temperature
and humidity
-40~80℃
≤90%RH(no dewing)
Atmosphere environment
There should be no corrosive gas,flammable gas, oil fog
or dust etc. in the control cabinet.
Altitude Altitude: below 1,000m
Vibration
≤ 0.5G(4.9m/s
2
)10-60Hz
Atmospheric pressure
86kPa~106kPa
Guard level IP43
Environmental requirements
Installation method