GSK CNC Equipment Co., Ltd.
54
380V AC
power
input
380V AC
transformer
DA98B
servo unit
380V 220V
220V
220V
380V
380V
6
7
SRDY
DG
relay
24V
power
Hold
motor
Hold coil
KM1
Used for cutting off hold signal
against work table falling
down while power down
980TD
system
System
switch power
KM1
KM1
Switch-on
Switch-off
220V
L
220V
N
KM1
Typical wiring diagram of GSK
980TD matched with DA98B servo
unit on turning machine
6.4 Parameter adjustment for machining characteristics improvement
DA98B basic parameter adjustment diagram