EasyManuals Logo

GW Instek GPP-3060 User Manual

GW Instek GPP-3060
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #158 background imageLoading...
Page #158 background image
GPP-3060/6030 User Manual
158
Command
:MONItor[1|2]:VOLTage:CONDition{<V|>V|=V|
NONE},{AND|OR|NONE}
Function
Queries the voltage monitor condition of monitor
(active channel).
Description
{<V|>V|=V|NONE} Sets voltage monitor
condition as “ <V”(<voltage),“ >V”(>voltage) ,
“=V”(=voltage)or “ NONE”(none-monitored
voltage).
{AND|OR|NONE} Practical monitor condition is
the logical composition of voltage, current and
power. ,”AND ” (and), “OR” (or), “ NONE”(none-
logical pattern) .
Example
:MONItor2:VOLTage:CONDition <V,AND
Sets the CH2 voltage monitor condition of monitor
(active channel) as <voltage,and.
Command
:MONItor[1|2]:VOLTage:CONDition?
Function
Queries the voltage monitor condition for the
current monitor (active channel).
Example
:MONItor2:VOLTage:CONDition?
Queries the CH2 voltage monitor condition for the
current monitor.
Command
:MONItor[1|2]:VOLTage[:VALue]{<value>|MINi
mum|MAXimum}
Function
Sets the voltage monitor value of monitor (active
channel).
Description
<value) ranges from 0 to the maximum voltage
value of the active channel.
Example
:MONItor2:VOLTage 5
Sets the CH2 voltage monitor value of monitor as
5V (active channel).