REMOTE CONTROL
139
Source and Load Commands
Command
:SOURce[1|2]:CURRent <NRf>
Function
Sets the current level.
Description
<NRf>
0.0000-6.2000 (Refer to the specification
sheet for MAX value).
Example
:SOURce2:CURRent 1.0005
Sets the current level to 1.0005A for CH2.
Note
About CH3, The current value can not be set.
Command
ISET<X>:<NR2>
Function
Sets the current level.
Description
X 1= CH1, 2= CH2
<NR2>Decimal number, range 0-6.200A.
Example
ISET1:2.234
Sets the CH1 output current to 2.234A.
Note
About CH3, The current value can not be set.
Command
:SOURce[1|2]:CURRent?
Description
Queries the current limit level.
Example
:SOURce2:CURRent?
Queries the current limit level on CH2.
Command
ISET<X>?
Function
Returns the output current setting.
Description
X 1= CH1, 2= CH2