BASIC OPERATION
37
Source Function
Description
Each channel is equipped with basic power
functions and able to display both settings
and read back value of V/I as well as output
status
Parameter
description
Vset
Set output voltage of active channel.
The range is as the following:
CH1/CH2:
0.000V-32.000V (GPP-3060)
0.000V-62.000V (GPP-6030)
CH3: 1.8V/2.5V/3.3V/5.5V
Iset
Set limited current of active channel.
The range is as the following:
CH1/CH2:
0.0000A-6.2000A (GPP-3060)
0.0000A-3.2000A (GPP-6030)
OVP
Set OVP. The range is as the
following:
CH1/CH2:
0.5V-35.0V (GPP-3060)
0.5V-65.0V (GPP-6030)
OCP
Set OCP. The range is as the
following:
CH1/CH2: