Example
:SEQUence2:TEMPlet:POINTs 10
Sets the CH2 overall points as 10.
Command
:SEQUence[1|2]:TEMPlet:POINTs?
Function
Queries the actively set overall points.
Example
:SEQUence2:TEMPlet:POINTs?
Returns the CH2 actively set overall points.
Command
:SEQUence[1|2]:TEMPlet:RISERate <value>
Function
Sets the rising degree of ExpRise.
Description
<value> Ranges from 0 to 10.
Example
:SEQUence2:TEMPlet:RISERate 10
Sets the rising degree of ExpRise as 10 for CH2.
Command
:SEQUence[1|2]:TEMPlet:RISERate?
Function
Queries the rising degree of the actively set
ExpRise.
Example
:SEQUence2:TEMPlet:RISERate?
Returns the rising degree of the actively set ExpRise
for CH2.
Command
:SEQUence[1|2]:TEMPlet:SELect
{SINE|PULSE|RAMP|UP|DN|UPDN|RISE|FAL
L}
Function
Selects templet type.
Description
SINE|PULSE|RAMP|UP|DN|UPDN|RISE|FAL
L
Example
:SEQUence2:TEMPlet:SELect SINE
Sets the selected templet type as SINE for CH2.
Command
:SEQUence[1|2]:TEMPlet:SELect?