6 - Maintenance
101
Greasing the Pump
The pump is greased as follows:
• Factory greased:
300 g grease into each lubrication point (A).
• Normal operation:
Greasing every 50 hours with 30 grams of grease into each
lubrication point (A). See also “50 Hours Service - Greasing
the Pump” on page 106.
• After disassembling the pump (diaphragm replacement, etc.):
Greasing with 200 grams of grease into each lubrication
point (A).
ATTENTION! In order to prevent excessive wear, it is important to
use a recommended lubricant (i.e. HARDI® part no. 28164600).
See “Recommended Lubricants” on page 95.
ATTENTION! The pump MUST be stopped during greasing!