ID5000 Series Smart Code Reader User Manual
60
Select Soft Trigger Active
If you select Soft Trigger Active as Line Out Activation Event, you can set its output delay time,
duration, and execute outputting signal manually.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.
Line Trigger Software
Click Execute for manually outputting the output signal.
Figure 8-46 Select Soft Trigger Active
Select Hard Trigger Active
If you select Hard Trigger Active as Line Out Activation Event, you can set its output delay time,
duration, trigger source, and trigger activation.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.
Hardware Trigger Source
It sets the hardware trigger source, including LineIn 0, LineIn 1, and LineIn 2.
Hardware Trigger Activation
It sets the trigger activation of input signal, including Rising Edge and Falling Edge.