2. You can editing the following parameters:
Door Magnetic: The Door Magnetic is in the status of Normal Closed (excluding special conditions).
Exit Button Type: The Exit Button Type is in the status of Remain Open (excluding special conditions).
Door Locked Time: After swiping the normal card and relay action, the timer for locking the door starts
working.
Door Open Duration by Card for Disabled Person: The door magnetic can be enabled with appropriate
delay after disabled person swipes the card.
Door Open Timeout Alarm: The alarm can be triggered if the door has not been close
Enable Locking Door when Door Closed: The door can be locked once it is closed even if the Door Locked
Time is not reached.
Duress Code: The door can open by inputting the duress code when there is duress. At the same time, the
client can report the duress event.
Super Password: The specific person can open the door by inputting the super password.
Dismiss Code: Input the dismiss code to stop the buzzer of the card reader.
Note: The Duress Code, Super Code, and Dismiss Code should be different.
3. Click Save button to save parameters.
4. Click Apply Parameters button to apply the updated parameters to the local memory of the device.
Editing Card Reader Information
Steps:
1. In the device list on the left, click to expand the door, select the card reader name and you can edit the
card reader information on the right.