Video Access Control Terminal User Manual
72
Select the access control device from the list on the left.
Click Add button to add a new linkage. You can select the event source as Event Linkage or Card Linkage.
Event Linkage
For the event linkage, the alarm event can be divided into four types: device event, alarm input, door event, and
card reader event.
Steps:
1. Click to select the linkage type as Event Linkage, and select the event type from the dropdown list.
For Device Event, select the detailed event type from the dropdown list.
For Alarm Input, select the type as alarm or alarm recovery and select the alarm input name from the
table.
For Door Event, select the detailed event type and select the door from the table.
For Card Reader Event, select the detailed event type and select the card reader from the table.
2. Set the linkage target, and switch the property from to to enable this function.
Host Buzzer: The audible warning of controller will be triggered.
Capture: The real-time capture will be triggered.
Reader Buzzer: The audible warning of card reader will be triggered.
Alarm Output: The alarm output will be triggered for notification.
Door: The door status of open, close, remain open, and remain close will be triggered.
Note: The door status of open, close, remain open, and remain close cannot be triggered at the same time.
3. Click Save button to save parameters.
4. Click Apply Settings to apply the updated parameters to the local memory of the device to take effect.
Card Linkage
Steps:
1. Click to select the linkage type as Card Linkage.
2. Input the card No. or select the card from the dropdown list.
3. Select the card reader from the table for triggering.
4. Set the linkage target, and switch the property from to to enable this function.
Host Buzzer: The audible warning of controller will be triggered.