Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 117/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1141
broken wire
Sensor Error: IOSetup2
Faulty Setup switch or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1241
circuit ground
1341
circuit battery
1441
module error
1541
output deactivated
1641
error +UB
1741
data error / CAN error
1841
timeout / CAN timeout
1941
safety error
1A41
parameter error
1B41
unspecified error
1C41
missing adjustment
1142
broken wire
Sensor Error: IOLuffUp1
Faulty Booming Up key
or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1242
circuit ground
1342
circuit battery
1442
module error
1542
output deactivated
1642
error +UB
1742
data error / CAN error
1842
timeout / CAN timeout
1942
safety error
1A42
parameter error
1B42
unspecified error
1C42
missing adjustment
1143
broken wire
Sensor Error: IOLuffUp2
Faulty Booming Up key
or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1243
circuit ground
1343
circuit battery
1443
module error
1543
output deactivated
1643
error +UB
1743
data error / CAN error
1843
timeout / CAN timeout
1943
safety error
1A43
parameter error
1B43
unspecified error
1C43
missing adjustment

Other manuals for Hirschmann qSCALE i2