Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 118/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1144
broken wire
Sensor Error:
IOCutByp1
Faulty system override
switch or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1244
circuit ground
1344
circuit battery
1444
module error
1544
output deactivated
1644
error +UB
1744
data error / CAN error
1844
timeout / CAN timeout
1944
safety error
1A44
parameter error
1B44
unspecified error
1C44
missing adjustment
1145
broken wire
Sensor Error:
IOCutByp2
Faulty system override
switch or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1245
circuit ground
1345
circuit battery
1445
module error
1545
output deactivated
1645
error +UB
1745
data error / CAN error
1845
timeout / CAN timeout
1945
safety error
1A45
parameter error
1B45
unspecified error
1C45
missing adjustment
1146
broken wire
Sensor Error: IOStopp1
Input from motor faulty
or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1246
circuit ground
1346
circuit battery
1446
module error
1546
output deactivated
1646
error +UB
1746
data error / CAN error
1846
timeout / CAN timeout
1946
safety error
1A46
parameter error
1B46
unspecified error
1C46
missing adjustment