Error
Code
Description
Cause
Notice/Solution
1147
broken wire
Sensor Error: IOStopp2
Input from motor faulty
or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1247
circuit ground
1347
circuit battery
1447
module error
1547
output deactivated
1647
error +UB
1747
data error / CAN error
1847
timeout / CAN timeout
1947
safety error
1A47
parameter error
1B47
unspecified error
1C47
missing adjustment
1148
broken wire
Sensor Error: IOStick1
Faulty joystick zero
position input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1248
circuit ground
1348
circuit battery
1448
module error
1548
output deactivated
1648
error +UB
1748
data error / CAN error
1848
timeout / CAN timeout
1948
safety error
1A48
parameter error
1B48
unspecified error
1C48
missing adjustment
1149
broken wire
Sensor Error: IOStick2
Faulty joystick zero
position input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1249
circuit ground
1349
circuit battery
1449
module error
1549
output deactivated
1649
error +UB
1749
data error / CAN error
1849
timeout / CAN timeout
1949
safety error
1A49
parameter error
1B49
unspecified error
1C49
missing adjustment