qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
114A
broken wire
Sensor Error: IO-
Voltage1
Faulty over voltage
detection input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
124A
circuit ground
134A
circuit battery
144A
module error
154A
output deactivated
164A
error +UB
174A
data error / CAN error
184A
timeout / CAN timeout
194A
safety error
1A4A
parameter error
1B4A
unspecified error
1C4A
missing adjustment
114B
broken wire
Sensor Error: IO-
Voltage2
Faulty over voltage
detection input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
124B
circuit ground
134B
circuit battery
144B
module error
154B
output deactivated
164B
error +UB
174B
data error / CAN error
184B
timeout / CAN timeout
194B
safety error
1A4B
parameter error
1B4B
unspecified error
1C4B
missing adjustment
114C
broken wire
Sensor Error: IOBy-
pA2B1
Faulty A2B override
switch or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
124C
circuit ground
134C
circuit battery
144C
module error
154C
output deactivated
164C
error +UB
174C
data error / CAN error
184C
timeout / CAN timeout
194C
safety error
1A4C
parameter error
1B4C
unspecified error
1C4C
missing adjustment