EasyManua.ls Logo

Hirschmann qSCALE i2 - Page 121

Hirschmann qSCALE i2
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 121/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
114D
broken wire
Sensor Error: IOBy-
pA2B2
Faulty A2B override
switch or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
124D
circuit ground
134D
circuit battery
144D
module error
154D
output deactivated
164D
error +UB
174D
data error / CAN error
184D
timeout / CAN timeout
194D
safety error
1A4D
parameter error
1B4D
unspecified error
1C4D
missing adjustment
114E
broken wire
Sensor Error:
IOBypTW1
Faulty Rope-end over-
ride switch or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
124E
circuit ground
134E
circuit battery
144E
module error
154E
output deactivated
164E
error +UB
174E
data error / CAN error
184E
timeout / CAN timeout
194E
safety error
1A4E
parameter error
1B4E
unspecified error
1C4E
missing adjustment
114F
broken wire
Sensor Error:
IOBypTW2
Faulty Rope-end over-
ride switch or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
124F
circuit ground
134F
circuit battery
144F
module error
154F
output deactivated
164F
error +UB
174F
data error / CAN error
184F
timeout / CAN timeout
194F
safety error
1A4F
parameter error
1B4F
unspecified error
1C4F
missing adjustment

Other manuals for Hirschmann qSCALE i2