EasyManua.ls Logo

Hirschmann qSCALE i2 - Page 122

Hirschmann qSCALE i2
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 122/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1150
broken wire
Sensor Error: IOTele1
Faulty Tele 1 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1250
circuit ground
1350
circuit battery
1450
module error
1550
output deactivated
1650
error +UB
1750
data error / CAN error
1850
timeout / CAN timeout
1950
safety error
1A50
parameter error
1B50
unspecified error
1C50
missing adjustment
1151
broken wire
Sensor Error: IOTele2
Faulty Tele 2 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1251
circuit ground
1351
circuit battery
1451
module error
1551
output deactivated
1651
error +UB
1751
data error / CAN error
1851
timeout / CAN timeout
1951
safety error
1A51
parameter error
1B51
unspecified error
1C51
missing adjustment
1152
broken wire
Sensor Error: IOTele3
Faulty Tele 3 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1252
circuit ground
1352
circuit battery
1452
module error
1552
output deactivated
1652
error +UB
1752
data error / CAN error
1852
timeout / CAN timeout
1952
safety error
1A52
parameter error
1B52
unspecified error
1C52
missing adjustment

Other manuals for Hirschmann qSCALE i2