Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 123/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1153
broken wire
Sensor Error: IOTele4
Faulty Tele 4 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1253
circuit ground
1353
circuit battery
1453
module error
1553
output deactivated
1653
error +UB
1753
data error / CAN error
1853
timeout / CAN timeout
1953
safety error
1A53
parameter error
1B53
unspecified error
1C53
missing adjustment
1154
broken wire
Sensor Error: IOTele5
Faulty Tele 5 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1254
circuit ground
1354
circuit battery
1454
module error
1554
output deactivated
1654
error +UB
1754
data error / CAN error
1854
timeout / CAN timeout
1954
safety error
1A54
parameter error
1B54
unspecified error
1C54
missing adjustment
1155
broken wire
Sensor Error: IOTele6
Faulty Tele 6 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1255
circuit ground
1355
circuit battery
1455
module error
1555
output deactivated
1655
error +UB
1755
data error / CAN error
1855
timeout / CAN timeout
1955
safety error
1A55
parameter error
1B55
unspecified error
1C55
missing adjustment