qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1156
broken wire
Sensor Error: IOTele7
Faulty Tele 7 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1256
circuit ground
1356
circuit battery
1456
module error
1556
output deactivated
1656
error +UB
1756
data error / CAN error
1856
timeout / CAN timeout
1956
safety error
1A56
parameter error
1B56
unspecified error
1C56
missing adjustment
1157
broken wire
Sensor Error: IOTele8
Faulty Tele 8 input or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1257
circuit ground
1357
circuit battery
1457
module error
1557
output deactivated
1657
error +UB
1757
data error / CAN error
1857
timeout / CAN timeout
1957
safety error
1A57
parameter error
1B57
unspecified error
1C57
missing adjustment
1158
broken wire
Sensor Error:
IOTeleSw1
Tele position initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1258
circuit ground
1358
circuit battery
1458
module error
1558
output deactivated
1658
error +UB
1758
data error / CAN error
1858
timeout / CAN timeout
1958
safety error
1A58
parameter error
1B58
unspecified error
1C58
missing adjustment