Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 127/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
115F
broken wire
Sensor Error:
IOTeleSw8
Tele position initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
125F
circuit ground
135F
circuit battery
145F
module error
155F
output deactivated
165F
error +UB
175F
data error / CAN error
185F
timeout / CAN timeout
195F
safety error
1A5F
parameter error
1B5F
unspecified error
1C5F
missing adjustment
1160
broken wire
Actuator Error: IOSafety
Faulty Safety Cut-off
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1260
circuit ground
1360
circuit battery
1460
module error
1560
output deactivated
1660
error +UB
1760
data error / CAN error
1860
timeout / CAN timeout
1960
safety error
1A60
parameter error
1B60
unspecified error
1C60
missing adjustment
1161
broken wire
Actuator Error: IOCut
Faulty Load Cut-off
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1261
circuit ground
1361
circuit battery
1461
module error
1561
output deactivated
1661
error +UB
1761
data error / CAN error
1861
timeout / CAN timeout
1961
safety error
1A61
parameter error
1B61
unspecified error
1C61
missing adjustment

Other manuals for Hirschmann qSCALE i2