Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 128/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1162
broken wire
Actuator Error: IOSpeed
Faulty Speed Cut-off or
the output module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1262
circuit ground
1362
circuit battery
1462
module error
1562
output deactivated
1662
error +UB
1762
data error / CAN error
1862
timeout / CAN timeout
1962
safety error
1A62
parameter error
1B62
unspecified error
1C62
missing adjustment
1163
broken wire
Actuator Error: IORig-
ging
Faulty Rigging-mode
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1263
circuit ground
1363
circuit battery
1463
module error
1563
output deactivated
1663
error +UB
1763
data error / CAN error
1863
timeout / CAN timeout
1963
safety error
1A63
parameter error
1B63
unspecified error
1C63
missing adjustment
1164
broken wire
Actuator Error: IOTeleIn
Faulty Telescoping In
Enable output or the
output module is defec-
tive
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1264
circuit ground
1364
circuit battery
1464
module error
1564
output deactivated
1664
error +UB
1764
data error / CAN error
1864
timeout / CAN timeout
1964
safety error
1A64
parameter error
1B64
unspecified error
1C64
missing adjustment