Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 128/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Faulty Speed Cut-off or
the output module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
Actuator Error: IORig-
ging
Faulty Rigging-mode
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
Faulty Telescoping In
Enable output or the
output module is defec-
tive
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap