qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Actuator Error: IOTele-
Out
Faulty Telescoping Out
Enable output or the
output module is defec-
tive
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
Actuator Error: IO-
BoomUp
Faulty Booming Up
Enable output or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
Actuator Error: IO-
BoomDown
Faulty Booming Down
Enable output or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap