qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1165
broken wire
Actuator Error: IOTele-
Out
Faulty Telescoping Out
Enable output or the
output module is defec-
tive
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1265
circuit ground
1365
circuit battery
1465
module error
1565
output deactivated
1665
error +UB
1765
data error / CAN error
1865
timeout / CAN timeout
1965
safety error
1A65
parameter error
1B65
unspecified error
1C65
missing adjustment
1166
broken wire
Actuator Error: IO-
BoomUp
Faulty Booming Up
Enable output or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1266
circuit ground
1366
circuit battery
1466
module error
1566
output deactivated
1666
error +UB
1766
data error / CAN error
1866
timeout / CAN timeout
1966
safety error
1A66
parameter error
1B66
unspecified error
1C66
missing adjustment
1167
broken wire
Actuator Error: IO-
BoomDown
Faulty Booming Down
Enable output or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1267
circuit ground
1367
circuit battery
1467
module error
1567
output deactivated
1667
error +UB
1767
data error / CAN error
1867
timeout / CAN timeout
1967
safety error
1A67
parameter error
1B67
unspecified error
1C67
missing adjustment

Other manuals for Hirschmann qSCALE i2