WIKA Mobile Control LP  
1540 Orchard Drive 
Chambersburg, PA 17201 
 
qSCALE maestro (PLC v01.00.00) Service Manual / Issue E (HMI v1.0.0) 04/2018 / rbm.
 
Service : (717) 217-2250 
Parts / Sales : (717) 217-2269 
www.wika-mc.com 
 
51
/76 
 
 
HIRSCHMANN MCS 
6.7 Load Sensing 
 Please note that the load displayed by the RCL is not a direct measurement, but a calculated value 
that is based on many factors. Factors included that are outside of the measured values include: 
 
  Operator settings such as: 
Operating mode/configuration 
Parts of Line/Reeving 
Outrigger position 
 
  Rigging parts such as: 
Hook block weight 
Sling weights, etc. 
Tip height (length of load line used) 
Boom weights 
 
  Boom attachments such as: 
Stowed jibs 
Glass jib, telescopic jib, etc. 
 
Before checking the system for a load-reading problem, make sure all of the above has been ruled out. 
When you still feel the system is reading a sensor wrong and thus displaying an incorrect load, use the 
following: 
 
Use the previous sections and the individual sensor signal displayed on the screen to double-check the 
following: 
  boom length reading 
  angle transducer reading 
  pressure transducer readings 
 
 
If all are correct, use the zero setting and calibration screens to zero pressure transducers, calibrate 
angle, and length. If you still have a problem, replace pressure transducer(s).