1. Motor clamp.
2. Fix the motor lead wires by the cord clamp.
3. Rubber Bush.
4. Pass the motor lead wires through the square hole of the electrical box.
5. Electrical Box.
6. Pass the motor lead wires through the harness lifter and connect them to the PCB3 (for MOF1) and PCB5 (for MOF2).
7. Harness Lifter.
8. Partition plate.
¿ Removing electrical box
1 Remove the service cover following Removing service cover, see on page 414.
2 Remove the upper cover following Removing upper cover, see on page 415.
3 Remove four (4) screws which fix the electrical box.
4 Pull up and remove the electrical box.
1. Electrical box.
2. Upper cover.
3. Compressor.
N O T E
• Wiring must be removed to dismount the electrical box.
1 Remove the 4-way valve coil from the 4-way valve. : Removing four-way valve coil, see on page 425.
2 Remove the expansion valve coil from the expansion valve. : Removing electronic expansion valve coil,
see on page 424.