6 Optional functions
RAS-3HVRC2
SMGB0136 rev.0 - 07/2021
112
6.1.3.2 Function setting
No. Setting Item
7-Segment
Display
Contents
1
Circulator function at heating Thermo-
OFF
Not available (default setting)
Heating Thermo-OFF fan intermittent operation
2 Night-shift (low noise)
Not available (default setting)
Night-shift
3
Cancellation of outdoor ambient
temperature limit
Not available (default setting)
For heating
For cooling
For cooling/heating
4 Defrost
Not available (default setting)
Defrost for Cold Area (Change of Defrost Condition)
Defrost for Warm Area (Change of Defrost Condition)
Defrost for Extreme Cold Area 1 (Change of Defrost Condition)
Defrost for Extreme Cold Area 2 (Change of Defrost Condition)
5 SLo (Fan Speed) defrost setting
Not available (default setting)
Slo wind defrosting setting
6 No Function
Not available (default setting)
No setting
7 Priority capacity mode
Not available (default setting)
Cooling capacity correction mode 1
Cooling capacity correction mode 2
Cooling capacity correction mode 3
8 Priority Cooling Capacity Mode
Not available (default setting)
Priority Cooling Capacity Mode
9 Priority Heating Capacity Mode
Not available (default setting)
Priority Heating Capacity Mode
10 No Function
Not available (default setting)
No setting
11
Indoor Expansion Valve Opening
During Heating Operation Stoppage
Not available (default setting)
Heating Operation Stoppage 1
Heating Operation Stoppage 2
12
Indoor Expansion Valve Operating
during Heating Thermo-OFF
Not available (default setting)
Heating Thermo-OFF 1
Heating Thermo-OFF 2
13
Outdoor Expansion Valve Initial
Opening for Heating
Not available (default setting)
Initial Opening for Heating 1
Initial Opening for Heating 2
14 Low Noise Setting
Not available (default setting)
Low noise setting 1
Low noise setting 2
Low noise setting 3
Low noise setting 1
Low noise setting 2
Low noise setting 3
Low noise setting 1
Low noise setting 2
Low noise setting 3
15 Demand Function Setting
Not available (default setting)
Demand Function always enabled
16 Wave Function Setting
Not available (default setting)
Wave Function enabled
17
Protection of Decrease in Outlet
Temperature for Cooling
Not available (default setting)
Outlet Temperature for Cooling 1
Outlet Temperature for Cooling 2