2 Optional parts and installation
Optional parts and installation for RAS-3HVRC2
SMGB0136 rev.0 - 07/2021
29
2
2.1.2 Wind guard WSP-264
Specications
Material Galvanized sheet metal + baked painting
1
2
Color UTOPIA Beige (Mussel code: 2.5Y8/2)
Weight 4.0 kg
Accessories
Unit xing
screw
4 x [M5 (SUS) x 30]
Wind guard
xing screw
10 x [M5 (SUS) x 12]
Installation manual
Installation restriction
“Guard net” “Air ow guide” or “Snow
protection hood” is not available to install
with Wind guard
1 4-6x10 Long Hole
2 5 (Both Sides) - M5 Screw (attachement)
Installation
1 Attach the air ow guide to the air discharge grille with four (4) screws (supplied).
2 The xing holes are located at 4 positions on the grille. (Screw tightening torque 2.4 - 3.1 N.m)
3 Do not remove the air discharge grille for air ow guide installation.
! CAUTION
If the air guide is installed without discharge grille it may cause injury due to rotating fan.
One wind guard cover installation
202
Wind guard
Air discharge grille
4 x M5 xing screw
(Accessories)
Service space (In case of upward air discharge)
• In case of right and left sides air discharge enough space for air
discharge is required.
• The downward air discharge is also available. In such case install the
base under the unit to secure enough space for air discharge.
• In case of serial units installation air discharge should be upward.
Min.150 mm