75
The charger can provide a number of fault codes. The fault codes are indicated by the error
LED (with the ! above it) and the stand-by LED (by the 'on' symbol). These light up or flash
alternatingly. Information about the fault codes and possible solutions is provided in the
table below.
fault
Cause / solution
Single flashes
Battery does not hold a charge. Have
battery checked by your dealer.
Double flashes
Possible short-circuit in the battery. Have
battery checked by your dealer.
Triple flashes
The battery voltage is too high for the
selected charge mode. Check the battery
and charge mode.
Continuously lit error
LED
Reversed polarity. Swap the battery
connections.
Continuously lit
orange LED
The battery voltage is too low to detect
the charge.
Temporarily connect an extra battery to
the machine via the start assistance
terminals or contact your dealer.