System (2)
4 - 6 Model 1010 Application Pack CB Part No.: 4418024 - Rev. 1
Programming Manual
System of Units Sets the system of units (either Metric or US) to be used throughout the
instrument. The arm setup menu sets the units (volumetric or mass) for
a particular arm.
Select one of the following options:
Metric - ISO units*
US units
Constraints: Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
Corrected (Base)
Temperature
Sets the basis of temperature correction to convert gross or ambient
volumes to net or corrected volumes.
Constraints: Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
Select one of the following options:
Base 15 C*
Base 20 C
Constraints: Only if System of Units = Metric - ISO units
or
The following option is available:
Base 60F*
Constraints: Only if System of Units = Units US
Litre/Liter Spelling Allows for alternate spelling of litre.
Constraints: Only if Units = Metric - ISO Units
Select one of the following options:
LITRE*
LITER
Volume Decimals Determines the number of decimal points displayed on all totals and
rates (except the accumulated total, which is fixed at no decimal points)
Constraints: Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
1* (for example, 2344)
0.1 (for example, 2344.3)
4.2.5 Batch Type
Selects whether the instrument will batch on gross or net values.
Constraints: Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
Select one of the following options:
GROSS*