Additive Lines (6)
8 - 6 Model 1010 Application Pack CB Part No.: 4418024 - Rev. 1
Programming Manual
Constraints:
Available only when the injection point is enabled and assigned an
arm.
Select one of the following options:
Enable
Disable*
Additive Deviation
Basis
Enter the number of cycles over which an average is calculated.
Constraints:
Available only when the injection point is enabled and assigned an
arm.
Additive Deviation alarm enabled
Enter a value in following range:
1 to 20 (10*)
Additive Volume
deviation
Enter the additive deviation percentage.
If the average of the additive amount injected exceeds or is lower than
the additive deviation percentage specified for that injection point,
additive alarm will be recorded.
Constraints:
Available only when the injection point is enabled and assigned an
arm.
Additive Deviation alarm enabled
Enter a value in following range:
1 to 100 (10*)
8.5.3 K-Factor Menu
K Factor Sets the K-Factor for the additive flow meter in pulses/product unit.
Constraints: Available only when the injection point is enabled and
assigned an arm.
Enter a value in the following range:
0.01 to 99999.99 (2600.0)
8.5.4 Meter Factor Menu
Meter Factor Use to manually enter the correction factor to take into account
variations in the calibration of the Flow meter.
The correction factor is applied to the Meter K-FACTOR. The Meter
Factor may be calculated automatically by the instrument or
entered manually. For more information, see “Automated Proving” in
the Operator Manual.