4 - 30 Model 1010 Application Pack CB Part No.: 4418024 - Rev. 1
Programming Manual
ARM INPUT n After selecting any arm input from the ARM MESSAGES menu, the
instrument displays the following screen.
This screen allows selection of an entry from a list of choices. Scroll
through list using the DISPLAY key. The list contains standard and fixed
messages.
Select one of the following options:
Standard*
Vapour System
Valve Position
Additive Alarm
Arm Park
Arm Position
4.9 Opto Outputs (28)
The Opto Outputs sub-menu of the System menu allows the operator to
configure the various opto outputs.
NOTE: This a global parameter. For example, if this parameter is set to Flow meter
B pulses, all Opto Outputs will output the Flow B pulse from their respective
flow meter.
4.9.1 Opto Outputs
Opto Outputs Select one of the following options:
Flow meter A
Flow meter A pulses can be provided at the output
Flow meter B
Flow meter B pulses can be provided at the output.
ARM INPUT 1 27
(STANDARD)
ARM INPUT 1