Loading Arms (3)
5 - 6 Model 1010 Application Pack CB Part No.: 4418024 - Rev. 1
Programming Manual
Low Flow Alarm If enabled, the instrument issues an alarm if the low flow limits are
exceeded.
Select one of the following options
ENABLE
DISABLE*
Low Percentage The instrument triggers the low flow low alarm if the arm low flow is less
than LOW PRECENTAGE and the low flow alarm is enabled.
Enter a value in the following range:
1.0 to 50.0 (1.0*)
High Percentage The instrument triggers the low flow high alarm if the arm low flow
exceeds HIGH PRECENTAGE and the low flow alarm is enabled.
Enter a value in the following range:
1.0 to 50.0 (1.0*)
Low Flow Alarm Delay The time that the instrument waits until the volume reaches (LOW
FLOW ALARM DELAY) before triggering low flow alarm.
Enter a value in the following range:
10 to 300 (10.0*)
5.2.6 Additive Setup
Use the Additive Setup sub-menu to set the volume of product that must
pass through the loading arm for each Additive Injection.
Continue Add Batch on
alarm
Allows enabling or disabling the Continue Additive Batch on alarm
feature. When enabled, the additive exception results in an alarm being
registered via the AL command, but the batch will be paused and the
instrument displays an option to restart without the faulty additive.
Constraints: Only available if the arm has internal additives assigned
and enabled.
Select one of the following options:
Enable
Disable*
Manual Product Pacing Allows the use of product pacing quantity.
Constraints: Only available if additive type is selected as external
additive.
Select one of the following options:
ENABLE
DISABLE*