Loading Arms (3)
5 - 7 Model 1010 Application Pack CB Part No.: 4418024 - Rev. 1
Programming Manual
Arm n Additive Flush
Volume
When using additives, such as dyes, selecting an additive flush volume
makes sure that the final volume does not contain any additive. Select 0
to disable flush volume.
Enter a value in the following range:
0 to 999 (0*)
Constraints: Only available if additive is configured as pulsed additive.
NOTE: If a flush volume is entered, the injections will occur more frequently before
the flush volume. Once the flush volume is reached, no additive is injected.
NOTE: Additive flush volume for other types of additive injectors is entered as part
of the Arm Recipe under the Recipes menu.
Arm x Product Pacing
Qty
Sets how often an additive injection will occur. For example, enter “200”
to inject additive once for every 200L of product, at 100L, 300L, 500L
etc.
Enter a value in the following range:
0 to 9999 (200*)