4 - 22 Model 1010 Application Pack CB Part No.: 4418024 - Rev. 1
Programming Manual
Load Scheduling
Remote Authorise Selects whether the instrument will use remote authorising of personnel
and/or vehicle. This is typically used when there are greater than 2750
personnel or vehicle authorisation numbers and they cannot all be
stored in the instrument. For more information, see the “Remote
Authorisation in the 1010CB Protocol Manual. Authorisation type must
be configured for either personnel or vehicle.
Constraints: Authorisation type must be configured for either
personnel or vehicle.
Select one of the following options:
Enable
Disable*
Comms Timeout Sets the time allowed for no communications between the instrument
and the computer before a communications timeout error is triggered. A
comms timeout of 0 disables the communications timeout error.
Constraints: Only if Terminal Automation Mode = Load Scheduling or if
Remote Authorisation is enabled.
Enter a value in the following range:
0 to 600 (0*)
4.7.3 Options
The Options sub menu of the Communication menu allows selection of
a debug option. If enabled, the SLIP command will return the error
status code along with the NAK. Refer to the Protocol Manual for more
details.
Select one of the following options:
Enable
Disable*