36 | Performance Series HQA Digital Video Recorder Remote User Guide
Figure 3-2 Encoding Interface
Table 3-2 Encoding Configurations
Setting Description
Channel Select a channel from the dropdown list
Video Enable Click to enable the extra video stream. Enabled by default.
Code Stream Type Select from Regular, MD (Motion Detection), and Alarm.
You can select different encoding frame rates for different
recorded events.
The DVR system supports active control frame function (ACF),
which allows you to record in different frame rates.
For example, you can use a high frame rate to record
important events, and configure a lower frame rate for
recording scheduled events. ACF allows you to set different
frame rates for motion detection recording and alarm
recording.
Compression Main Stream: Select from H.264H, H.264, or H.264B.
Sub Stream: Select from MJPEG, H.264H, H.264, or H.264B.
Smart Codec Reduces the video bit stream for non-important recorded
video, to maximize storage space.
Select either Stop or Start.