This product is compliant with ULC 60839 -11-1 Grade 1. Below tables lists the evaluated
mandatory requirements.
Note Optional ULC 60839-11-1 requirements has not been evaluated by UL.
Table 7-1
Access Point Interface requirements Yes/No Grade 1 OP/M
When the release time is system-defined, the permitted value shall not be
less than 3 s
Yes M
Provide access control for entry into a protected (controlled) area Yes M
Access granted conditional upon credential validity (blocked, suspended,
invalid)
Yes M
Table 7-2
Table 3 –Indication and annunciation requirements Display/Alert/Loggin
g/Indication
Yes/No Grade 1 OP/M
Visual and/or audible indication required
when access is granted
Indication Yes M
Table 7-3
Access levels Yes/No Grade
The minimum ratio between number of possible user codes and number of
allocated codes shall be at least 1 000 to 1 when system is using recognition
of a valid user by memorized information only e.g.: up to 10 users 4 digits, up
to 100 users – 5 digits, up to 1 000 users – 6 digits, etc
Yes M
In normal mode of operation the system shall use complete token information
(facility code and card number, or unique card number) for recognition
Yes M
Tokens with coding system structure visible to unaided human eye shall not
be used
Yes M
The token identity number readable on the token not to be a direct
representation of the entire coding
Yes M