MPA1 User Guide
Monitoring/Managing Doors
The panel supports 1 Door. The door status screen provides status for each door’s egress,
status, and tamper and also status of the door lock relay.
The Door Status screen enables you to:
• View the current status of each input (Normal, Alarm, Cut, Short, Unshunt/Shunt).
• Shunt or un-shunt any input. Shunt means that the input’s change of state is ignored.
This way you can allow a door to be held open without signaling an alarm. The default
state of an input point is "unshunted."
• Restore the input to its schedule. A schedule is a specified time period during which
the input will be shunted and the alarm deactivated (for schedule management, see
Configuring Time Management on page 30).
• View the current status of each output (Energized, De-energized).
• Pulse, energize, or de-energize the Door Lock relay.
• Restore the Door Lock to its schedule.
Navigating to the Spaces & Doors tab:
Click to open the menu, then click Device Management.
Card Holder Name Reports a Card Holder name on events where the Card
Number is an actual card in the system.
Filter by Card Holder Name: You can filter alarms and
events by the Card Holder Name by clicking the filter icon
next to Card Holder Name in the header, and then
entering a card holder name.
Clear All Filters Click to clear all display filters (Date/Time; Space; Severity;
Type; Cred-PIN/Site; Card Holder Name).
Download
Alarms/Events
For generating reports. See Reporting on page 86.
Download Web Events For generating reports. See Reporting on page 86. Web
Events include logins with invalid passwords and logging
in/out, for example.
Table 3-1 Alarms & Events Fields
Field Description