Troubleshooting 81
Cooling errors
Cooling errors occur when too few fans are installed in the enclosure or when the existing fans are not
installed in an effective configuration. Cooling errors can occur on blades, storage blades, or interconnect
modules.
To correct a cooling error:
1. Use the arrow buttons to navigate to Fix This, and press OK.
2. Review and complete the corrective action suggested by the Insight Display. In most cases, you must
either add fans to the enclosure, correct the fan configuration, or remove the indicated components.
Location errors
Location (installation) errors occur when the component is not installed in the appropriate bay. Location
errors can occur on blades, storage blades, power supplies, and fans.
To correct a location error:
1. Use the arrow buttons to navigate to Fix This, and press OK.
2. Review and complete the corrective action suggested by the Insight Display. Remove the indicated
component, and install it into the correct bay. The Insight Display will indicate the correct bay number.
Configuration errors
Configuration errors can occur if the interconnect modules are installed in the wrong bays or if mezzanine
cards are installed in the wrong connectors in the blade. Configuration errors can occur on blades and
interconnect modules.
To correct a configuration error:
1. Use the arrow buttons to navigate to Fix This, and press OK.
2. Review and complete the corrective action suggested by the Insight Display. Depending on the error
received, do one of the following:
o Remove the indicated interconnect module and install it into the correct bay (the Insight Display
indicates the correct bay).
o Remove the blade to correct the mezzanine card installation (the Insight Display will indicate the
correct bay). For information on installing the mezzanine card, see the server-specific user guide on
the Documentation CD.
Device failure errors
Device failure errors occur when a component has failed. Device failure errors can occur on all components,
including:
Server blades
Storage blades
Power supplies
Interconnect modules
Onboard Administrator modules

Table of Contents

Other manuals for HP BladeSystem c7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP BladeSystem c7000 and is the answer not in the manual?

HP BladeSystem c7000 Specifications

General IconGeneral
Form Factor10U
Number of Bays16
Redundant PowerYes
Redundant FansYes
Maximum Blade Servers16 half-height or 8 full-height
Operating Temperature10° to 35°C (50° to 95°F)
Power SuppliesUp to 6
Cooling Fans10
ManagementOnboard Administrator
Interconnect ModulesUp to 8
Networking OptionsEthernet, Fibre Channel, InfiniBand
CompatibilityHP ProLiant and Integrity server blades
Relative Humidity10% to 90% (non-condensing)

Related product manuals