Figure 29 Processor Location
WARNING! Ensure that the system is powered-down and all power sources have been
disconnected from the server prior to removing or replacing a processor.
Voltages are present at various locations within the server whenever an AC power source is
connected. This voltage is present even when the main power switch is in the off position.
Failure to observe this warning could result in personal injury or damage to equipment.
CAUTION: Failure to properly complete the steps in this procedure will result in erratic system
behavior or system failure. For assistance with this procedure, contact your local HP Authorized
Service Provider.
Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety
precautions could result in damage to the server.
Avoid contact with the processor heatsink if the server has been operating prior to the installation
of the additional processor. The heatsink will be safe to touch after the cover has been removed
for a few seconds.
Removing a Processor
To remove a processor, perform the following steps:
1. Turn off the system and disconnect all cables.
2. Remove the cover. See “Removing and Replacing the Cover (page 30).
3. Remove the sheet metal air duct.
4. Disconnect the power pod cable from the power connector on the system board.
34 Removing and Replacing Components

Table of Contents

Other manuals for HP Integrity rx1620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx1620 and is the answer not in the manual?

HP Integrity rx1620 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx1620
CategoryServer
LanguageEnglish

Related product manuals