260 • STN Reference HP NonStop SSH Reference Manual
zstn-evt-auditcoll-service value is 1023
"<STN process name> AUDITCOLL <window> <IP-address> <IP-port> service <service-name> Outcome
<outcome>"
• CAUSE: Generated on a session connection attempt to a service or dedicated window. Outcome is GRANTED
or DENIED. This event is written to the specified collector, not to the standard $0 EMS event collector.
• EFFECT: None; informational only.
• ACTION: None; informational only.
zstn-evt-auditcoll-connect value is 1024
"<STN process name> AUDITCOLL connect <window> <IP-address> <IP-port> <encrypted> Client Info <text>
• CAUSE: Generated when a new session is accepted from a remote workstation. <encrypted> is SECURE or
PLAIN. This event is written to the specified collector, not to the standard $0 EMS event collector.
• EFFECT: None; informational only.
• ACTION: None; informational only.
zstn-evt-auditcoll-disconnect value is 1025
"<STN process name> AUDITCOLL disconnect <window> <IP-address> <IP-port>
• CAUSE: A session has terminated. This event is written to the specified collector, not to the standard $0 EMS
event collector.
• EFFECT: None; informational only.
• ACTION: None; informational only.
zstn-evt-auditcoll-wsinfo value is 1026
"<STN process name> AUDITCOLL <window> <IP-address> <IP-port> wsinfo <wsinfo> Outcome <6>
• CAUSE: WSINFO is in effect. <wsinfo> is the information returned by the workstation emulator. <outcome>
is GRANTED if the session was allowed to continue or DENIED if the WSINFO requirements were not met.
This event is written to the specified collector, not to the standard $0 EMS event collector.
• EFFECT: None; informational only.
• ACTION: None; informational only.
zstn-evt-max-outq value is 1027
"<STN process name> STN window <2> exceeds max_outq <3>"
• CAUSE: A terminal session has a large amount of output that cannot be sent to the terminal.
• EFFECT: The session is terminated.
• ACTION: This is usually caused by an ill-behaved application. If the problem persists, contact support.