Loading...
WDM
connection
WDM
connection
25145b
Fabric A1
Local
Fabric A1
Remote
Fabric B1
Local
Fabric B1
Remote
Figure 80 Fully redundant WDM configuration using two long-distance fiber optic links
.
The configuration in Figure 80 is high cost, but is fully redundant.
HP supports the following third-party WDM products and configurations:
CWDM and DWDM systems supported by the switch vendors.
WDM devices that are configurable to a data rate of 1 Gb/s, 2 Gb/s, 4 Gb/s, 8 Gb/s, or 10
Gb/s
Up to 500 km at 1 Gb/s, over a WDM link (switch model dependent). On certain Fibre Channel
switches, there may be reduced performance at this distance. See
Storage product interface and transport distance rules on page 171.
Performance levels depend on the number of buffers available in the switch and the amount of
application data.
For information about HP-certified third-party WDM products, see
Certified third-party WDM, iFCP, and SONET products on page 352.
Extended fabric settings for Fibre Channel switches
When extending fabrics with Fibre Channel long-distance transceivers or WDM, it is important to
maintain the performance of ISL connections. See Features on page 100 for information about the
B-series Extended Fabrics license.
B-series switch settings
An Extended Fabrics license is required for B-series switches when extending a fabric beyond 10 km.
See the HP StorageWorks Fabric OS 5.3x administrator guide for B-series extended fabric switch
settings, available at
http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=SupportManual&
lang=en&cc=us&docIndexId=179111&taskId=101&prodTypeId=12169&prodSeriesId=1143936.
NOTE:
The HP C-series CWDM solution is not supported on B-series switches. See
Certified third-party WDM products on page 353 for B-series supported WDM devices.