BehaviorPoint in timeSetting
All LUNs remain on the surviving control-
ler. There is no failback except if a host
moves the LUN using SCSI commands.
On controller failback
The units are brought online to Controller
1.
At initial presentation
Path A - Failover Only
If cache data for a LUN exists on a partic-
ular controller, the unit will be brought
online there. Otherwise, the units are
brought online to Controller 1.
On dual boot or controller resynch
All LUNs are brought online to the surviv-
ing controller.
On controller failover
All LUNs remain on the surviving control-
ler. There is no failback except if a host
moves the LUN using SCSI commands.
On controller failback
The units are brought online to Controller
2.
At initial presentation
Path B - Failover Only
If cache data for a LUN exists on a partic-
ular controller, the unit will be brought
online there. Otherwise, the units are
brought online to Controller 2.
On dual boot or controller resynch
All LUNs are brought online to the surviv-
ing controller.
On controller failover
All LUNs remain on the surviving control-
ler. There is no failback except if a host
moves the LUN using SCSI commands.
On controller failback
The units are brought online to Controller
1.
At initial presentation
Path A - Failover/Fail-
back
If cache data for a LUN exists on a partic-
ular controller, the unit will be brought
online there. Otherwise, the units are
brought online to Controller 1.
On dual boot or controller resynch
All LUNs are brought online to the surviv-
ing controller.
On controller failover
All LUNs remain on the surviving control-
ler. After controller restoration, the units
that are online to Controller 2 and set to
Path A are brought online to Controller 1.
This is a one-time occurrence. If the host
then moves the LUN using SCSI com-
mands, the LUN will remain where moved.
On controller failback
The units are brought online to Controller
2.
At initial presentation
Path B - Failover/Fail-
back
EVA4400 operation38

Table of Contents

Other manuals for HP StorageWorks 4400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 4400 and is the answer not in the manual?

HP StorageWorks 4400 Specifications

General IconGeneral
BrandHP
ModelStorageWorks 4400
CategoryStorage
LanguageEnglish

Related product manuals