4. Under System Shutdown click Power Down. If you want to delay the initiation of the shutdown,
enter the number of minutes in the Shutdown delay field.
The controllers complete an orderly shutdown and then power off. The disk enclosures then power
off. Wait for the shutdown to complete.
5. If your management server is an SMA and you are not using it to manage other storage arrays,
shut down the SMA. From the SMA user interface, click Settings > Maintenance > Shutdown.
Shutting down the storage system from the array controller
1. Push and hold the on/standby power button on the front panel of the EVA4400 (see callout 9
in Figure 11 or Figure 12).
2. Wait 4 seconds. The power button and the green LED start to blink.
NOTE:
Holding the power switch button for less than 4 seconds does nothing.
3. Between 4 and 10 seconds, release the button. The button continues to blink and the firmware
starts the shutdown process (LED becomes solid amber, flushes the cache, disables the batteries).
4. After 10 seconds, the power shuts down.
Starting the storage system
1. Verify that each Fibre Channel fabric switch connected to the HSV controllers is powered up and
fully booted. The power indicator on each switch should be on.
If you must power up the SAN switches, wait for them to complete their power-on boot process
before proceeding. This may take several minutes.
2. Power on the circuit breakers on both EVA rack PDUs. Verify that all drive enclosures are operating
properly. The status indicator and the power indicator should be on (green).
3. Power on the controller enclosure, which powers on both controllers.
4. After allowing the EVA4400 to start, connect to the web-based Operator Control Panel (WOCP)
to verify the display of the storage system name and WWN.
5. Start HP Command View EVA and verify connection to the storage system. If the storage system
is not visible, click HSV Storage Network in the Navigation pane, and then click Discover in the
Content pane to allow HP Command View EVA to discover the array.
NOTE:
If the storage system is still not visible, check zoning and cabling, and verify correct
configuration of server connectivity. If necessary, reboot the management server to
re-establish the communication link.
6. Check the storage system status using HP Command View EVA to ensure everything is operating
properly. If any status indicator is not normal, check the log files or contact your HP-authorized
service provider for assistance.
HP StorageWorks 4400 Enterprise Virtual Array user guide 41

Table of Contents

Other manuals for HP StorageWorks 4400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 4400 and is the answer not in the manual?

HP StorageWorks 4400 Specifications

General IconGeneral
BrandHP
ModelStorageWorks 4400
CategoryStorage
LanguageEnglish

Related product manuals