Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WRetry the operation.Please retry operation.87006005
WA logical path does not exist
between the MCU and the
RCU. Check the path status
on RCU Status dialog box,
and reestablish the paths
with Edit Path.
Logical Path between the MCU and the
RCU is not active.
87016005
WRefresh the window, and
check whether the specified
volume is a M-VOL.
The specified volume is not a M-VOL.87026005
WThe number of paths is less
than the minimum number
specified on the RCU Option
dialog box. Check the
number of paths, establish
the minimum number of
paths, and retry the
operation.
The specified number of Paths is less
than the Minimum number of Paths on
RCU Option screen.
87036005
WCheck the paths status and
reestablish the paths.
The specified number of paths is less
than the minimum number of paths on
the RCU option screen due to a
communication error between the MCU
and the RCU.
87046005
WEither a communication error
occurred between the MCU
and the RCU, or the CHA
has become blocked. Please
contact HP Technical
Support.
The path could not be deleted due to a
communication error between MCU
and RCU.
87056005
WSpecify a correct value.Parameter specified by Remote Copy
operation is invalid.
87066005
WCheck the pair status for
Continuous Access
Synchronous. If the
requested R-VOL is in a
permissible status, please
retry the operation.
The pair status of the R-VOL is not valid.87086005
EAll channel adapters are not
active for Continuous Access
Synchronous. Please contact
HP Technical Support.
Remote Copy operation was rejected.87096005
WThe pair status does not
permit this operation. Verify
the pair status, and if the
operation is permitted retry.
The pair status of the specified volume
is not valid.
87106005
WCheck if the specified Port,
GID, LUN, CU, or LDEV
number exists in the storage
system.
The Port, GID, LUN, CU, or LDEV
number of the specified volume is
incorrect.
87116005
140 Message (part code group 6nnn)