Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
iCancel the preset suspension
in the CT group, then retry
the operation.
Preset Suspension is effective in the CT
Group.
88176005
iCancel the preset suspension
in the CT group, then retry
the operation.
Preset Suspension is effective in the CT
Group.
88186005
WSelect another volume.A volume cannot be used as an R-VOL
when:
• it is in an intervention-required
condition.
• it is in a protection condition.
• it is in unusable condition.
• it is a secondary volume of Business
Copy or a target volume of Business
Copy Z.
• it is a reserved volume of Business
Copy or Business Copy Z.
• it is a volume reserved by Auto LUN.
• it is used by Continuous Access
Journal Z.
88196005
WThe Continuous Access
Synchronous operation
failed, because R-VOL has
one of the following
conditions:
• The volume is blocked.
• The volume is under
maintenance.
• The volume is copying
data (correction copy or
drive copy).
• The volume is in the
correction access
condition.
The specified R-VOL is not a permissible
condition of Remote Copy.
88206005
WVerify the configuration of
the specified R-VOL.
The specified R-VOL is not recognizable
from the connection port.
88216005
WCheck whether the volume
is in a usable condition. If
the volume is usable, please
contact HP Technical
Support.
An I/O Error occurred on the R-VOL,
or the R-VOL is in an unusable
condition.
88226005
EPlease contact HP Technical
Support.
An internal error occurred.88266005
WRetry the operation in a few
minutes.
If this problem persists, select
the volumes where the error
occurred, execute the Delete
Pair (Pairsplit-S) command
with the Force option, then
retry the operation.
Please wait a few minutes and retry the
Add Pair(Paircreate)/Resume
Pair(Pairresync).
88276005
150 Message (part code group 6nnn)