Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
EIf the extended shared
memory (SM #2) is not
installed in RCU, install the
shared memory to RCU
according to the installation
instruction of the extended
shared memory for remote
copy ("Shared Memory Size
Configuration" dialog box),
then create a pair.
If SM #2 is installed in RCU,
you cannot create any more
pairs because the number of
pairs has already reached
the maximum that can be
created by the system.
No more space is left in RCU for
differential management.
89066005
EInstall the extended shared
memory to RCU according
to the installation instruction
of the extended shared
memory for remote copy
("Shared Memory Size
Configuration" dialog box).
The extended SM is not equipped in
RCU.
89076005
WSpecify a correct value.Invalid parameter.89086005
EPlease contact HP Technical
Support.
A Port exchange error occurred.89096005
EPlease contact HP Technical
Support.
A Port exchange error occurred.89106005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the port.89116005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the port.89126005
WRefresh the window, then
retry the operation.
If the same problem persists
despite retrying, please
contact HP Technical
Support.
Invalid port type.89136005
WThe multiplatform feature has
already been installed in the
storage system. Verify the
configuration of the storage
system.
Multi platform feature already installed
in subsystem.
89146005
WRefresh the window, then
retry the operation.
If the same problem persists
despite retrying, please
contact HP Technical
Support.
The port type exchange operation is
rejected because the host(s) is(are)
processing the port type exchange.
89156005
156 Message (part code group 6nnn)